Circuit-test DMR-3600 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Multimeter Circuit-test DMR-3600 herunter. TM1700-series Circuit Breaker Analyzer System Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 13
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
TM1700-series
Circuit Breaker Analyzer System
Provides reliable and accurate test results
in noisy high voltage substations
Four standard models. Full stand-alone
functionality or data acquisition models
without user interface.
Fast and safer with DualGround™ testing,
both sides of breaker grounded
On-screen assistance with connection
diagrams and test template Wizard
All models can be controlled via computer
Description
The TM1700 series circuit breaker analyzers utilizes some of the
ground breaking technology from the top of the line version
TM1800. There are four models starting from PC-remote controlled
to fully stand-alone. All models can be controlled from a computer
using the well proven data management and analyzing software
CABA Win.
The robust design offers powerful technology that assists the user
to achieve efficient and reliable circuit breaker testing. All inputs and
outputs on the instrument are designed to withstand the challeng-
ing environment in high-voltage substations and industrial environ-
ments. Galvanically isolated inputs and outputs makes it possible to
perform all relevant measurements in one test, eliminating the need
for new setup and re-connections.
The patented DualGround™ method makes the testing safe and
time saving by keeping the circuit breaker grounded on both sides
throughout the test.
The timing measurement inputs are using a patented Active Interfer-
ence Suppression algorithm to ensure correct timing and accurate
PIR (Pre-Insertion Resistor) values even at high capacitively coupled
interference currents.
The adaptive and easy-to-use software allow the user to perform
the test by simply turning the test switch without the need for
settings. The operator is only one click away from advanced help
functions such as connection diagrams. The 8” color touch screen,
with on-screen keyboard, allows the user to efficiently operate this
high-level interface.
TM1700-series
Circuit Breaker Analyzer System
Select – Connect – Inspect
Working with TM1700
means fast and easy
testing. Testing is
done with a three-step
process.
Select
First step is to select a
suitable template from
the template library
depending on number
of contacts per phase,
motion or not, resistor
contacts and more.
Connect
Second step is to con-
nect the test leads ac-
cording to the graphical
help screen. Separate
help screens for each-
cable.
Inspect
Third step is to turn
the “Measure” knob.
The measurement is
performed, analyzed and
the results displayed on
the screen. Magnifica-
tion and compare func-
tions are available..
Seitenansicht 0
1 2 3 4 5 6 ... 12 13

Inhaltsverzeichnis

Seite 1 - TM1700-series

TM1700-seriesCircuit Breaker Analyzer System▪▪Provides reliable and accurate test results in noisy high voltage substations▪▪Four standard models. Ful

Seite 2 - Testing with DualGround

TM1700-seriesCircuit Breaker Analyzer System10Rotary transducer, Novotechnic IP6501 (analog)Linear transducer, LWG 150Linear transducer, TS 25Rotary t

Seite 3 - Features and benefits

TM1700-seriesCircuit Breaker Analyzer System11SDRM202SDRM Cable Extension cable XLR, GA-01005Cable XLR, GA-00760Cable reels, 20 m (65.5 ft), 4 mm sta

Seite 4 - Application examples

TM1700-seriesCircuit Breaker Analyzer System12TM1700 – ModelsTM1710Including: ▪ Control 3 ch. (Auxiliary 3 ch.) ▪ Timing M/R 6 ch. ▪ Digital 6 ch. ▪ C

Seite 5 - Motion measurements

TM1700-seriesCircuit Breaker Analyzer SystemSWEDEN Megger Sweden AB Eldarvägen 4, Box 2970 SE-187 29 TÄBY T +46 8 510 195 00 F +46 8 510 195 95 E s

Seite 6 - Vibration analysis

TM1700-seriesCircuit Breaker Analyzer System2With only one side grounded the induced current can reach values high enough to be harmful or lethal for

Seite 7 - Specifications TM1700-series

TM1700-seriesCircuit Breaker Analyzer System31 2 3 4 5 6 71 215 16 17 19 15 20 21 22 2310111218914138Features and benefits1. Input for external clamp-

Seite 8 - Optional accessories

TM1700-seriesCircuit Breaker Analyzer System4Application examplesFirst trip measurementWhen a fault occurs on a transmission or distribution line, it

Seite 9

TM1700-seriesCircuit Breaker Analyzer System5TimeOpenSpeed calculation pointsDamping zoneArcing zoneContact closureClosedStrokePositionMotion diagram

Seite 10

TM1700-seriesCircuit Breaker Analyzer System6current (if the current is permitted to reach its highest value) is a di-rect function of the coil’s resi

Seite 11

TM1700-seriesCircuit Breaker Analyzer System7Specifications TM1700-seriesGeneralSpecifications are valid after 30 minutes warm up time. System time bas

Seite 12 - TM1700 – Models

TM1700-seriesCircuit Breaker Analyzer System8Digital sectionGeneralNo. of channels 6Supported types Incremental transducers, RS422Time base inaccuracy

Seite 13 - NEW Accessories

TM1700-seriesCircuit Breaker Analyzer System9Item Description Art. No.TS 25 25 mm (1”) travel Incl. cable 1.0 m (3.3 ft)XB-30033Linear – DigitalTP1 30

Kommentare zu diesen Handbüchern

Keine Kommentare