Circuit-test DMR-1100 Bedienungsanleitung Seite 11

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 21
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 10
11
4.5. Reset - S8
If Switch 8 is placed in the ON position, the system will
automatically reset one minute after delay.
If switch 8 is left in the OFF position, the ERROR/FAIL
indication will continue. The unit may be manually reset
by a STOP/RESET command.
3 Plays, 5 Second Pause (Maintained Closure):
(1) (2) (3) (1) (2) (3)
Play 5 Sec Play 5 Sec Play Play 5 Sec Play 5 Sec Play etc.....
5. AUX CONNECTOR WIRING(J2)
Pin # Color Function
1 Blue Start 1
3 Orange Stop
4Black OV
5 Green Test
7Brown Start 2
9 Slate Start 3
11 Yellow Start 4
13 Violet Start 5
15 White Start 6
All start commands are done by providing a contact closure to Pin
#4 (OV). Use J1 connector for power, audio out, and play relay.
Seitenansicht 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 20 21

Kommentare zu diesen Handbüchern

Keine Kommentare